Features of Pilot magnet valve
2016-01-20 by bridge
Pilot
magnet valve, when energized, rely on electromagnetic force lifting the stem, the pilot valve port open, when the solenoid valve on the pressure relief chamber through the pilot hole, around the main spool is formed on the lower parts of high pressure, pressure difference in , the fluid pressure pushes the main spool to move up to the main valve port open; when off, the spring force and the gravity of the main valve stem is reset, the solenoid valve chamber pressure increases, the fluid pressure pushes the main spool moves down the main valve port is closed.
Features: Pilot diaphragm structure, low function. Protective membrane structure design, life expectancy doubled. Piping can be installed at any angle, to enhance the level of life is best piped coil up. Coil protection grade IP65. Suitable medium: liquid, water, hot water, gas, oil, gas and other fluid pressure higher upper limit can be any installation (to be customized) but fluid pressure conditions must be met.