relief valve
Related "Relief Valve" Products
Related "Relief Valve"Blog
Glow Bar System |
2016-03-23 |
In a glow bar system, the glow bar igniter and pilot valves are wired in series, meaning electricity must pass through the glow bar and then to the safety valve. The glow bar blocks current to the gas valve through electrical resistance that declines as the bar’s temperature rises. When the bar reaches yellow heat, suffic...
In a glow bar system, the glow bar igniter and pilot valves are wired in series, meaning electricity must pass through the glow bar and then to the safety valve. The glow bar blocks current to the gas valve through electrical resistance that declines as the bar’s temperature rises. When the bar reaches yellow heat, sufficient to ignite the gas, it allows passage of enough electricity to open the Propane Control Valve.
View Details
the ball is rotating gas burner valve to the gas burner valve |
2016-03-18 |
The working principle of the ball is rotating Gas Control Valves to the gas burner valve flow or occlusion. When rotate 90 °, gas
burner safety valve in the inlet and outlet shall all be present
spherical, thereby cutting flow. Use only the operation of the rota...
The working principle of the ball is rotating Gas Control Valves to the gas burner valve flow or occlusion. When rotate 90 °, gas
burner safety valve in the inlet and outlet shall all be present
spherical, thereby cutting flow. Use only the operation of the rotary
gas burner valve and 90 ° of the rotation of the small torque can be
tightly closed. Full equality for the media coelom provides resistance
is small, straight flow channel. Are commonly believed to be the most
suitable gas burner valve open and close finish use directly, but in
recent years, development has been designed, give it a gas burner valve
throttle valve and the purpose of flow control. gas cooker safety valve itself
is the main characteristics of compact structure, easy operation and
maintenance of water, solvent, acid, and the general media work of
natural gas, as well as the media of poor working conditions, such as
oxygen, hydrogen peroxide, methane and ethylene. Gas burner of the ball
valve can be as a whole, or can be modular.
View Details
Technical terms of relief valve |
2016-03-15 |
Pressure relief valve (PRV) or Pressure Release valve (PRV) or
pressure safety valve (PSV): The difference is that PSVs have a manual
lever to activate the valve in case of emergency. Most PRVs are spring
operated. At lower pressures some use a diaphragm in place of a spring.
The oldest PRV designs use a weight to seal the valve.Set pressur...
Pressure relief valve (PRV) or Pressure Release valve (PRV) or
pressure safety valve (PSV): The difference is that PSVs have a manual
lever to activate the valve in case of emergency. Most PRVs are spring
operated. At lower pressures some use a diaphragm in place of a spring.
The oldest PRV designs use a weight to seal the valve.Set pressure: When the system pressure increases to this value, the
PRV opens. The accuracy of the set pressure often follows guidelines set
by the American Society of Mechanical Engineers (ASME).Relief valve (RV): A valve used on a liquid service, which opens
proportionally as the increasing pressure overcomes the spring pressure.Safety valve (SV): Used in gas service. Most SVs are full lift or snap acting, in that they pop completely open.Safety relief valve (SRV): A relief valve that can be used for gas
or liquid service. However, the set pressure will usually only be
accurate for one type of fluid at a time.Pilot-operated relief valve
(POSRV, PORV, POPRV): A device that relieves by remote command from a
pilot valve which is connected to the upstream system pressure.Low-pressure safety valve (LPSV): An automatic system that relieves
by the static pressure of a gas. The relieving pressure is small and
near the atmospheric pressure.Vacuum pressure safety valve (VPSV): An automatic system that
relieves by the static pressure of a gas. The relieving pressure is
small, negative and near the atmospheric pressure.Low and vacuum pressure safety valve (LVPSV): An automatic system
that relieves by the static pressure of a gas. The relieving pressure is
small, negative or positive, and near the atmospheric pressure.Pressure vacuum release valve (PVRV): A combination of a vacuum
pressure and a relief valve in one housing. Used on storage tanks for
liquids to prevent implosion or over pressure.Snap acting: The opposite of modulating, refers to a valve that
"pops" open. It snaps into full lift in milliseconds. Usually
accomplished with a skirt on the disc so that the fluid passing the seat
suddenly affects a larger area and creates more lifting force.Modulating: Opens in proportion to the overpressure.
View Details
Construction of relief valve |
2016-03-11 |
Most relief valves simply lift (open) at a preset pressure and reset (shut) when the pressure drops slightly below the lifting pressure. They do not maintain flow or pressure at a given amount, but prevent pressure from rising above a specific level when the system is temporarily overloaded.Main system relief valves are generally installed between ...
Most relief valves simply lift (open) at a preset pressure and reset (shut) when the pressure drops slightly below the lifting pressure. They do not maintain flow or pressure at a given amount, but prevent pressure from rising above a specific level when the system is temporarily overloaded.Main system relief valves are generally installed between the pump or pressure source and the first system gas stoves freestanding. The valve must be large enough to allow the full output of the hydraulic pump to be delivered back to the reservoir. In a pneumatic system, the relief valve controls excess pressure by discharging the excess gas to the atmosphere.Smaller relief valves, similar in design and operation to the main system relief valve, are often used in isolated parts of the system where a check valve or directional control valve prevents pressure from being relieved through the main system relief valve and where pressures must be relieved at a set point lower than that provided by the main system relief. These small relief valves are also used to relieve pressures caused by thermal expansion (see glossary) of the fluids. Figure 6-11 shows a typical relief valve. System pressure simply acts under the valve disk at the inlet to the valve. When the system pressure exceeds the force exerted by the valve spring, Gas Top Burner Valve disk lifts off of its seat, allowing some of the system fluid to escape through the valve outlet until the system pressure is reduced to just below the relief set point of the valve.All relief valves have an adjustment for increasing or decreasing the set relief pressure. Some relief valves are equipped with an adjusting screw for this purpose. This adjusting screw is usually covered with a cap, which must be removed before an adjustment can be made. Some type of locking device, such as a lock nut, is usually provided to prevent the adjustment from changing through vibration. Other types of relief valves are equipped with a handwheel for making adjustments to the valve. Either the adjusting screw or the handwheel is turned clockwise to increase the pressure at which the valve will open. In addition, most relief valves are also providedwith an operating lever or some type of device to allow manual cycling or gagging the valve open for certain tasks.
View Details
Work principles of relief valve |
2016-02-24 |
Shunt relief valve is the floorboard of the diverter relief valve, flow relief valve and set flow diversion relief valve. Shunt relief valve, is to supply the same flow rate by the same energy to the two actuators in a hydraulic system (equivalent shunt), synchronized or fixed ratio relationship in order to achieve the speed of the two actuators. S...
Shunt relief valve is the floorboard of the diverter relief valve, flow relief valve and set flow diversion relief valve. Shunt relief valve, is to supply the same flow rate by the same energy to the two actuators in a hydraulic system (equivalent shunt), synchronized or fixed ratio relationship in order to achieve the speed of the two actuators. Set flow relief valve, it is from the two actuators collection flow or scaled back the amount of oil, in order to achieve the speed during synchronized or fixed ratio relationship. Shunt relief valve are both shunt relief valve and flow patio heater valve function.Structure diagram Figure 2 for the equivalent shunt relief valve. Let imported oil pressure P0, flow Q0, enter the relief valve is divided into two paths respectively through a fixed orifice two equal area 1, 2, respectively, into the oil chamber a, B, and then by the variable orifice 3, 4 by the oil outlet I and II leading to the implementation of elements of two. If the load is equal to two executive element, the outlet pressure p3=p4 diversion, because the relief valve two the size of flow completely symmetrical, so the output flow is symmetric, q1=q1=q0/2, and p1=p2. When P3 = P4 due to asymmetric load, and p3>p4, the Gas Grill Valve core to less movement in the middle position, because the total resistance of two branch on the same channel, will make the q1p2. Now the role the spool in the asymmetric hydraulic pressure under the left shift, the variable orifice 3 is increased, the orifice 4 is reduced, so that the Q1 increases, Q2 decreases, until Q1 = Q2, P1 = P2, the spool down stability in a new equilibrium position. That the flow of exports to the two actuators are equal, when the size of the two actuators are completely the same, the movement speed will be synchronized.
View Details
Installation and use of vacuum pressure release valve |
2016-02-22 |
Vacuum pressure relief valve is used to protect the top of the bin storage device granule thermal power, building materials, metallurgy, chemical and other industries used. When inflated exhaust and abnormal temperature changes, silo protection from excessive influence of positive and negative pressure.Installation and use of vacuum pressure releas...
Vacuum pressure relief valve is used to protect the top of the bin storage device granule thermal power, building materials, metallurgy, chemical and other industries used. When inflated exhaust and abnormal temperature changes, silo protection from excessive influence of positive and negative pressure.Installation and use of vacuum pressure release valve1, the gas safety relief valve is usually installed in the transformer tank cover or the side wall.2, the flange structure has a pressure release valve, you should configure the base flange.3, threaded products, hole size on the transformer cover, see installation dimensions.4, each product is equipped with a helmet, but it is only easy for users to do the whole seal transformer experimental use, it must be removed before running.
View Details
|