Manual Gas Valves
Related "Manual Gas Valves" Products
Related "Manual Gas Valves"Blog
Introduce Gas Burner Safety Valve |
2016-03-21 |
The heater valves for free standing cookers.with the safety desgin to be more safey and connector to a micorswitch to the auto ignitor.the Manual Gas Valves with a bracket at the top of the shaft....
The heater valves for free standing cookers.with the safety desgin to be more safey and connector to a micorswitch to the auto ignitor.the Manual Gas Valves with a bracket at the top of the shaft.
View Details
The cause of the scents of Gas stove |
2016-03-18 |
1.hose burst or connection, replace the hose and fixed;2. Gas Burner Safety Valve seal joint ageing, replace the sealing ring;3. combustion gas Burner Valve extension of the fault, replace the valve;4. put out the fire with troubleshooting, again.That is, from...
1.hose burst or connection, replace the hose and fixed;2. Gas Burner Safety Valve seal joint ageing, replace the sealing ring;3. combustion gas Burner Valve extension of the fault, replace the valve;4. put out the fire with troubleshooting, again.That is, from fire or flame, away from the fire (according to the previous solution) removed;Building joint leakage, repair or replacement joints.
View Details
Manual Gas Valves & Accessories |
2016-03-11 |
1.Complete Connection Kit for Propane.LP Conversion Kit includes: a 12 foot hose with quick release, propane regulator, LP Converter/Air Mixer, gas stove safety and all fittings.Suggested Use With The Following:Fire Pit Rings: 6", 12" and 18"/H-Burner: 12", 18" and 24"/T-Burner: 24", 36" and 48".2.Manual...
1.Complete Connection Kit for Propane.LP Conversion Kit includes: a 12 foot hose with quick release, propane regulator, LP Converter/Air Mixer, gas stove safety and all fittings.Suggested Use With The Following:Fire Pit Rings: 6", 12" and 18"/H-Burner: 12", 18" and 24"/T-Burner: 24", 36" and 48".2.Manual Straight Antique Brass Ball Valve. MSAB WALL/FLOOR STRAIGHT KEY VALVE KIT.Antique Brass Wall/Floor Straight Key Valve Kit. Includes Key, Flange w/ extender and Valve.3.Manual Straight Antique Brass Ball gas stove safety valve (High Capacity 3/4"). MSAB-HC WALL/FLOOR STRAIGHT KEY VALVE KIT.High Capacity Antique Brass Wall/Floor Straight Key Valve Kit; designed for use on wall or in floor. Includes Key, Flange w/ extender and Valve with a 3/4" inlet/outlet. This is our new 300k BTU valve that is perfect for "Large" outdoor fire effects.
View Details
How to prolong the service life of manual gas valve |
2016-02-17 |
Why straight trip manual gas valve stem smallerIt involves a simple mechanical principle: sliding friction, rolling friction small. Straight trip manual Manual Gas Valves stem up and down movement, packing slightly compressed, it will stem very tight package, have a greater difference. Therefore, the manual gas valve stem is designed to be ver...
Why straight trip manual gas valve stem smallerIt involves a simple mechanical principle: sliding friction, rolling friction small. Straight trip manual Manual Gas Valves stem up and down movement, packing slightly compressed, it will stem very tight package, have a greater difference. Therefore, the manual gas valve stem is designed to be very small, another commonly used filler of small friction coefficient of PTFE packing, in order to reduce hysteresis, but this problem is to send small stem, is easily bent, packing too short life. To solve this problem, the best way is to turn the manual gas valve stem with a tour, or rotary type control manual gas valve, the manual gas valve stem stroke than the straight stem diameter of 2 ~ 3 times, and use long life of the graphite packing, manual gas valve stem stiffness good, filling long life, but the friction torque is small, a small hysteresis.Why the angular travel manual gas valve cut-off pressure?Rotary type manual gas valve to cut off the pressure difference is larger, because the media in the spool or the manual gas valve on a board together on the shaft of the torque is very small, therefore, it can bear larger pressure difference.Why desalination water medium rubber lined butterfly Oven Safety Gas Valves, fluorine lined diaphragm manual gas valve short life?Removal of acid or alkali containing low concentration in salt water, they have more corrosive to rubber. Rubber corrosion performance for the expansion, aging, low intensity, with the rubber lining of the butterfly manual gas valve, diaphragm use the results are worse in its essence is caused by corrosion of rubber impatience. After the rubber lined diaphragm manual gas valve fluorine lined diaphragm manual gas valve for improved corrosion resistance performance is good, but the fluorine lined diaphragm manual natural gas valves diaphragm down then stand up to collapse were broken off, resulting in mechanical damage, shorter manual gas valve life. Now is the best way to special ball manual gas valve for water processing, it can be used to 5 ~ 8 years
View Details
The use of gas valve note |
2016-01-29 |
Easy one, why is a small two Copper Gas Valves opening work oscillationOn single core, when the medium is the flow of open type, the gas valve stability; when the medium is the flow of closed type, the gas valve of the poor stability. There are two spool gas valve seat, gas valve core in the flow of closed, open on the spool in the flow, so th...
Easy one, why is a small two Copper Gas Valves opening work oscillationOn single core, when the medium is the flow of open type, the gas valve stability; when the medium is the flow of closed type, the gas valve of the poor stability. There are two spool gas valve seat, gas valve core in the flow of closed, open on the spool in the flow, so that a small opening in the work, the flow of closed type spool gas valve is easy to cause the gas valve vibration, which is two seat gas valve can not be used for the work of a small opening reason.Two, why not double sealing gas valve as a shut-off gas valveSeat gas valve spool the advantage of force balance structure, allowing a large pressure difference, but it highlights the shortcomings of the two sealing surface is not also good contact, causing large leak. If it artificially, mandatory for cutting occasions, obviously not good, even if it made a lot of improvements (such as double sealed sleeve Heater Gas Valve), is not desirable.Three, what straight trip regulating gas valve anti blocking performance is poor, the angular travel gas valve anti blocking performanceVertical straight trip throttle gas valve spool, while the medium is the level of flow into the flow, the gas valve cavity flow must turn back street, so that the gas valve flow path becomes quite complex (such as the inverted "S" type). So, there are many dead, provides space, if things go on like this for the precipitation of the medium, causing blockage. Angular travel Gas Valves For Patio Heater throttle direction is the horizontal direction, the level of flows into the medium, the level of outflow, easy to medium is not clean away, simple flow path at the same time, also very little space medium precipitation, so the angular travel gas valve anti blocking performance.
View Details
Manual gas valve is in the pipeline fluid delivery system control unit |
2016-01-18 |
Gas valve on its installation position can be divided into two types of cylinder valves and piping valves to control the flow of gases and off. On the cylinder valve is accompanied by a safety device. Most of these valves to manual transmission mode, simple structure, small size, high strength, operating temperature of a 40- + 600C, the material ca...
Gas valve on its installation position can be divided into two types of cylinder valves and piping valves to control the flow of gases and off. On the cylinder valve is accompanied by a safety device. Most of these valves to manual transmission mode, simple structure, small size, high strength, operating temperature of a 40- + 600C, the material can adapt to the physical and chemical characteristics of the gas medium; ensure safe and reliable use of the following for how to choose a gas valve a brief description.Manual gas valve is in the pipeline fluid delivery system control unit, which is used to change the channel section and flow direction of medium, with diversion, off, adjust the throttle, check, diversion or overflow relief functions. For fluid control valve, the valve nominal diameter from the tiny instrument valve large diameter up to 10m of industrial piping valves. The valve can be under the influence of pressure, temperature, or other forms of sensor signals, according to a predetermined action requested, or do not rely on the sensor signal and a simple on or off, the valve being driven or automatic mechanism to open and close member for lifting, sliding spin pendulum or rotary motion, thus changing the size of its flow area to achieve its control function.
View Details
|