HOME | SITEMAP | CONTACT US | BLOG | 中文
About Us
Products
Appliance
Certification
R&D
Video
Contact Us
Products Keywords Link
   Gas Water Heater Control Valve
   Valve Burner
   Top Burner Valve
   Top Burner Control Valve
   Thermostatic Valves
   Stove Top Burner Valve
   Safety Valve Burner Valve
   Range Valve
   Range Top Burner Valve
   Range Dual Safety Valve
   Pilot Safety Valve
   Parts Oven Safety Valve
   Oven Safety Gas Valves
   Kitchenaid Range Parts
   Gas Top Burner Valve
   Gas Grill Valves
   Gas Cooker valve
   Gas Control Valves
   Gas Burner Valves
   Brass Gas Valves
   Gas Burner Cover
   Gas Stove Burner
   General Controls Gas Valve
   Gas Safety Valve
   Bbq Gas Valves
   Gas Grill Control Valve
   Manual Gas Valves
   Natural Gas Safety Valve
   Propane Control Valve
   Oven Gas Valve
Home >Parts Oven Safety Valve > Technical exchange: gas solenoid valve maintenance
Technical exchange: gas solenoid valve maintenance
2012-01-13 by seoer1

1, the solenoid valve from the pipeline when not removed, the internal parts should be tested with compressed air blowing the net and the net storage.

2, the solenoid valve when not in a long time, the manual valve before the valve should be closed, re-opening of the steam condensate removal solenoid valve should be clean, and the action for trial several times, to be put into use before switching to normal.

3, large valves should be regularly cleaned inside and outside and pull the armature surface dirt. Be careful not to damage the sealing surface.

4, the solenoid valve installation, shall pass into the media retries several times before to confirm the normal into official use.

5, it is recommended to use with units assigned responsibility for maintenance.

6, using a longer time, such as poor sealing between the piston and the Parts Oven Safety Valve seat, piston sealing surface can be re-polished, and then, and seat grinding.

7, work, pay attention to before and after the pressure gauge valve, required working pressure shall not exceed the rated pressure, working pressure must be within the rated pressure. When the pressure exceeds the rated working pressure or working pressure exceeding the rated pressure, the solenoid valve to stop the use of closed before and after the manual valve, solenoid valve to prevent explosion and leakage.